The dim bulb tester, the variac and the isolation transformer, a first power-up routine after a repair, and measuring a live amp.

Read it in the app ▸

The riskiest moment for an amp is the first switch-on after a repair, or after years in a closet. A shorted part or a cap fitted backwards can take out the power transformer, a rectifier or a set of tubes in seconds. Three bench tools make that moment safer for the amp and for you: the dim bulb tester, the variac and the isolation transformer. This level covers each one, and a first power-up routine. Level 1 covers where the danger is, and Level 2 draining the caps.

DANGER: LETHAL VOLTAGE. Everything in this level involves a live amp. Follow the one-hand rule, clip the meter's black lead to the chassis before power goes on, and never reach into a powered chassis. A dim bulb tester is mains wiring: build it in a closed, grounded box, or buy one ready-made.

The Dim Bulb Tester

A dim bulb tester puts an ordinary incandescent light bulb in series with the amp's power. If the amp tries to draw too much current, the bulb takes most of the voltage and lights up, and the amp gets too little to damage itself. The bulb is a current limiter and a current meter at once.

A dim bulb tester: the hot wire from the wall plug runs through an incandescent bulb before reaching the outlet the amp plugs into, while neutral and ground run straight through; at power-up the bulb flashes bright and settles dim if the amp is healthy, and stays bright if there is a short

The Variac

A variac is an adjustable transformer that brings the mains voltage up from zero. It lets you raise an amp's power slowly while watching for trouble.

The Isolation Transformer

An isolation transformer separates the amp's power from the mains ground, so touching a single live point and the ground is no longer a complete circuit.

When all three are on the bench, they go in this order: wall, isolation transformer, variac, dim bulb tester, amp.

First Power-Up After a Repair

  1. Look before you power up. Check your work against the layout: cap polarity, no stray solder or wire clippings, every tube in its correct socket.
  2. Connect a load. A speaker, or a dummy load of the right ohms and wattage. Never power a tube amp without one.
  3. Safety glasses on. A cap fitted backwards can burst.
  4. Through the dim bulb tester, with the standby switch on Standby, switch on. Watch the bulb settle and the heaters light.
  5. Standby to Play (or straight on, if the amp has no standby switch). Watch the bulb, and watch the power tubes: a plate glowing red means the tube is drawing far too much current. Switch off at once and check the bias.
  6. Clip the meter's black lead to the chassis with the power off, set it to DC volts, power up again, and with one hand check B+ at the first filter cap against the schematic.
  7. Check the bias with the bias probe or meter as the amp's design calls for. The Tube Bias Calculator shows the safe range for your tubes and plate voltage.
  8. Off the tester. Switch off, plug the amp straight into the wall, power up again, recheck B+ and bias at full voltage, then play it at low volume before turning it up.

Measuring a Live Amp

Some jobs need the amp on: checking B+, setting bias, finding a fault. The rules from Level 1 matter most here.

Try It

Before the next time you power up an amp you've worked on, write down the B+ the schematic expects at the first filter cap, and the bias range from the Tube Bias Calculator. Then measure both at steps 6 and 7 of the routine above and compare.

Read it in the app ▸