Draining the filter caps is the first job every time a tube amp comes open, before any other job. It takes a minute, and a meter proves it worked. Level 1 covers where the danger is and the bench rules; this level covers the drain lead, the order to work in, and the check. Level 3 covers powering an amp back up.
DANGER: LETHAL VOLTAGE. Filter capacitors can hold a lethal charge for hours or days after the amp is unplugged, and bleeder resistors can fail. Unplug the amp, drain every filter cap, and check each one with a meter before you touch anything. The Cap Drain & Bleeder Calculator shows the drain times.
Finding the Filter Caps
Filter caps are the largest electrolytic capacitors in the amp, and they sit near the power transformer and the rectifier.
- Can caps are tall aluminum cans standing on the chassis, often holding two to four caps in one can, with a lug for each.
- Board caps lie on a circuit board, or stand under a cover or in a "doghouse" box bolted to the chassis on many Fenders.
- Stacked caps. Many amps put two caps in series to handle the voltage, often with a resistor across each. Each cap in the stack has its own + terminal to drain and measure.
- The bias supply has its own smaller caps, at a negative voltage. Drain and measure them too.
A schematic or layout diagram for the amp shows where each one is. The first filter cap after the rectifier holds the highest voltage.
The Drain Lead
A drain lead is a resistor with an insulated alligator clip on each end. It empties a filter cap in a second or two, without the spark and the damage of a screwdriver across the terminals.
| Part | What to use |
|---|---|
| Resistor | about 2k to 100k ohms; 10k to 50k is a common choice. A 5 W or 10 W cement resistor handles the quick burst of energy easily |
| Clips | fully insulated alligator clips, on wire rated for the voltage |
| Covering | heat shrink over the resistor and every joint, so nothing bare is left to touch |
Under 1k is close to a dead short: a big current and a spark at the clip. Check the finished lead with a meter on ohms; it should read the resistor's value from clip to clip.
Draining, Step by Step
- Switch the amp off and unplug it. The standby switch alone does nothing for the caps.
- Clip one end of the lead to the chassis first. A ground lug or a chassis bolt with bare metal. Clipping ground first means the free end is the safe end while you place it.
- Clip the other end to the + terminal of a filter cap. One hand only; keep the other away from the chassis.
- Leave it 10 to 20 seconds, then move to the next cap. Do every one, including each cap in a stack and the bias caps (their + terminal goes to the chassis, so clip to the - side there).
- Caps hard to reach? Clip to the plate of V1, the first preamp tube: pin 1 or pin 6 on a 12AX7. The caps are linked through resistors that end at the preamp, so this drains the whole chain from the far end, but more slowly. Leave it at least a minute.
Measuring: The Part That Proves It
- Check the meter first on something you know is live, such as a 9 V battery. A meter with a flat battery or a blown fuse reads zero on everything.
- Set it to DC volts, on a range above the amp's B+ if the meter isn't auto-ranging.
- Clip the black lead to the chassis.
- Touch the red probe to each cap's + terminal and to the V1 plate, one hand only.
- You want under about 5 V everywhere. If any cap still reads high, drain it again and measure again.
Bleeders and Creep
- Bleeder resistors are soldered across the filter caps in many amps and drain them slowly after switch-off. They are a safety net, not a guarantee: a bleeder can burn open, and some amps never had them. The Cap Drain & Bleeder Calculator sizes one for your amp.
- Caps creep back up. An electrolytic that has been drained can recover a few volts, sometimes more, over the next minutes. Leave the drain lead clipped on while you work, or measure again whenever you come back to the bench.
- Every time. An amp that drained to zero yesterday gets drained and measured again today.
Try It
Make a drain lead and check it with your meter on ohms. Then, with an amp unplugged for at least a few minutes, measure its first filter cap before draining it. Many amps still hold real voltage after sitting, and seeing that number once is the best argument for never skipping the drain.
Level 3 covers powering up: the dim bulb tester, the variac, the isolation transformer, and the first power-up after a repair.