PALMATOWN/ tools / library Open the app ▸

Components · Relays

Relays - Level 3: The Numbers, Testing and Buying

Coil current and power, pull-in and drop-out voltages, contact ratings and materials, timing and bounce, life ratings, testing and choosing a relay.

Read it in the app ▸

This level is the reference: coil current and power, the voltages at which a relay pulls in and drops out, contact ratings and materials, timing and bounce, life ratings, testing, and choosing a relay.

Coil Numbers

Relay coil numbers: a 9 volt 153 ohm coil draws about 59 milliamps, pulls in above about 6.75 volts and releases below about 0.9 volts

A relay's coil is a resistor as far as the supply is concerned:

Coil current = coil voltage ÷ coil resistance

Coil power = coil voltage × coil current

A 9 V power relay with a 153 Ω coil, such as the Omron G2R-1-E, draws 9 ÷ 153 ≈ 59 mA and dissipates about 0.53 W. Small signal relays draw much less, often 10 to 30 mA at 9 V.

Data sheets give two more voltages:

So a relay pulls in reliably near its rated voltage and, once pulled in, holds on down to a much lower one. Two practical results: a 12 V relay on a 9 V supply sits right at its must-operate limit and may not pull in reliably, and some designs save power by applying full voltage to pull in, then a lower holding voltage.

Power budget: add the coil current to the pedal's other draw when sizing its supply (see the Power series). A pedal with two 59 mA relays energized draws over 118 mA for the relays alone.

Contact Ratings

Relay contact ratings for AC and DC, and gold contacts for signals versus silver contacts for power

Contacts are rated as a current at a voltage, separately for AC and DC, and usually for a resistive load:

Rating Example (a 16 A power relay)
AC 16 A at 250 V
DC 16 A at 24 V; much less at higher DC voltages
Maximum switching voltage e.g. 380 V AC, 125 V DC

DC is harder to break than AC because the arc has no zero crossing to snuff it out, so DC ratings fall steeply as the voltage rises. Inductive loads (motors, transformers) are rated lower again.

For speaker switching, work out the current from the amp's power and load:

Amp power Load Current
50 W 8 Ω 2.5 A
100 W 8 Ω 3.5 A
100 W 4 Ω 5.0 A
200 W 4 Ω 7.1 A

A relay rated well above these, such as 10 A to 16 A, leaves margin for peaks. The Power (W) Calculator works out the current for any amp and load.

Contact Materials and Minimum Load

Contacts Best for Notes
Gold-clad or bifurcated gold guitar-level audio, signals, logic stays clean at tiny currents; the gold wears off if used for heavy loads
Silver alloy (silver nickel, silver tin oxide) power, speakers, mains handles heavy current and arcing; at tiny currents, its surface film can make it noisy

Power relays often list a minimum switching load, such as 100 mA at 5 V. Below it, the contacts may not wipe themselves clean, which is fine for speaker current but makes a power relay a poor choice for guitar-level audio. Use a signal relay with gold contacts for audio, a power relay for speakers.

Contact resistance is typically under 0.1 Ω when new, far below a speaker's impedance.

Timing and Bounce

Figure Typical value Means
Operate time 5 to 15 ms from coil on to contacts switched
Release time 2 to 10 ms from coil off to contacts back
Bounce about 1 to 5 ms the contacts chatter as they land

The operate time is why a speaker switcher with break-before-make contacts has a short open gap, and why a resistor across each output is worth having. Bounce is part of why relay switching can click in audio; muting the output for a few milliseconds hides it. In digital circuits, bounce is handled by debouncing, as with switches.

A flyback diode slows the release slightly. Designs that need the fastest release add a zener or resistor in series with the diode.

Life Ratings

Switching speaker current at full power, or switching the mains, is what wears contacts. Switching speakers with the amp quiet, or muted, adds enormously to a relay's life.

DANGER: LETHAL VOLTAGE. Relays that switch the mains, or that sit inside a tube amp, must never be tested in place with power on unless you are trained for live high-voltage work. Unplug the equipment, drain any filter caps through a resistor and check them with a meter first. The Cap Drain & Bleeder Calculator explains how.

Testing

Testing a relay: coil resistance, then continuity from common to normally closed and normally open

With the relay out of circuit, or its circuit powered down:

  1. Coil resistance: should match the data sheet. OL means an open coil.
  2. Contacts with the coil off: COM to NC should beep (near 0 Ω); COM to NO should read OL.
  3. Apply the rated coil voltage from a bench supply or battery, observing polarity if the coil is polarized or has a built-in diode. The relay should click, and COM to NO should now beep while COM to NC reads OL.
  4. Contacts that read high, flicker or crackle are pitted or dirty. Sealed relays can't be cleaned; replace them.

Choosing a Relay

Check Look for
Coil voltage your supply voltage: 9 V for a pedal power supply, 12 V or 24 V where the equipment provides it
Coil current within what your driver and supply can provide
Contact form SPDT, DPDT, or more, for the job
Contact rating above the current and voltage you will switch, AC or DC
Contact material gold for audio signals, silver for speakers and power
Latching or not latching to save power or remember state
Package footprint, pin spacing and size for the board or chassis
Sealing sealed relays for dusty, touring use

Substituting: match the coil voltage and contact form exactly, and use a contact rating equal to or higher than the original. Pinouts vary between makers even for the same footprint, so check the data sheet before swapping.

Try It

Work out the coil current of a relay you have with the formula above, then add it to your pedalboard's power budget from the Power series. Then use the Power (W) Calculator to check that its contacts can carry your amp's speaker current.

Read it in the app ▸