The right replacement cap is about ratings first and brand second. This level covers voltage, capacitance, temperature and the other numbers that matter, and the traps: polarity, series stacks, and caps too big for a tube rectifier. Level 1 covers which caps age; Level 3 covers doing the job.
DANGER: LETHAL VOLTAGE. A tube amp's filter capacitors can hold a lethal charge for hours or days after it is unplugged, and the cap job is done right where that charge lives. Unplug the amp, drain every filter cap, and check each one with a meter before you touch anything. The Cap Drain & Bleeder Calculator shows how. New to working inside an amp? Start with On the Bench: Safe Practice.
Voltage
A filter cap's voltage rating must be above the highest voltage it ever sees, not the B+ on the schematic.
- At switch-on, before the tubes warm up and draw current, the B+ rises above its working value, most of all in amps with a solid-state rectifier, or with the standby switch on Standby.
- Measure the B+ with the amp on and on Standby, and use the higher figure.
- Leave a margin: about 20% above the highest reading is a common rule. A 450 V supply that rises to 480 V on standby wants 600 V caps, or two in series.
Capacitance
- Same value is always safe.
- A modest increase on the filter caps (not the first one on a tube rectifier) tightens the low end and lowers hum.
- The first cap after a tube rectifier has a maximum: too much capacitance stresses the rectifier at switch-on. The tube's data sheet gives it; stay at or below the original.
Temperature and Life
- 105°C rated caps last much longer than 85°C ones in a hot chassis.
- Lead spacing and size matter for fitting: check the board or the mounting before buying.
The Traps
- Polarity. Filter caps go plus to B+. Bias supply caps are the other way round: plus to ground, minus to the negative bias voltage. A cap fitted backwards can vent or burst.
- Series stacks. Where two caps share a high voltage in series, each with a resistor across it, replace both caps with the same value, and check the resistors (they're often 100k to 220k, and they burn).
- Can caps. Multi-section caps in one can are still made for many classic amps; or the sections can be replaced with separate caps under the chassis.
Coupling, Bypass and Tone Caps
- Coupling caps: replace only if leaking (Level 1), or if they're old paper types. Use film caps rated 400 to 630 V. Changing good coupling caps changes the tone and rarely fixes anything.
- Cathode bypass caps: low voltage (25 to 50 V is typical); same value, and mind the polarity.
- Tone caps and ceramics: leave them, unless one has failed.
Try It
List every filter and bias cap in your amp with its value, voltage, polarity and position. That list is your parts order, and the map you'll follow in Level 3.