A "cap job" is replacing the capacitors in an amp that have aged out. It's one of the most common repairs on an old tube amp, and one of the most misunderstood: some caps wear out and some don't, and replacing the wrong ones changes the tone for nothing. This level covers which caps age, why, and the signs. Level 2 covers choosing replacements; Level 3 covers doing the job.
DANGER: LETHAL VOLTAGE. A tube amp's filter capacitors can hold a lethal charge for hours or days after it is unplugged, and the cap job is done right where that charge lives. Unplug the amp, drain every filter cap, and check each one with a meter before you touch anything. The Cap Drain & Bleeder Calculator shows how. New to working inside an amp? Start with On the Bench: Safe Practice.
The Caps in a Tube Amp
| Cap | Job | Ages? |
|---|---|---|
| Filter caps (big electrolytics near the power transformer) | smooth the B+ and store its energy | yes: the main reason for a cap job |
| Bias supply caps (small electrolytics, fixed-bias amps) | smooth the negative bias voltage | yes, and a failure can let the power tubes run away |
| Cathode bypass caps (small electrolytics on the preamp and cathode-biased power tubes) | set gain and tone at each stage | yes, more slowly |
| Coupling caps (film or paper, between stages) | pass the signal, block the DC | rarely wear out; old paper and some early types can leak DC |
| Tone and small ceramic or mica caps | shape the tone | almost never |
Why Electrolytics Age
An electrolytic capacitor holds a liquid or paste electrolyte. Over the years it dries out, faster when hot, and the cap loses capacitance and gains internal resistance. A long-unused amp has a second problem: the insulating layer inside the cap weakens, so it can fail when power returns. Many techs treat filter caps of 15 to 25 years as due, sooner in an amp that runs hot.
The Signs
- Hum that has grown louder over time, steady whatever the volume.
- Ghost notes or a fuzzy "farting" edge on low notes, and a soft, flabby response when the amp works hard.
- Motorboating: a putt-putt sound as the stages feed each other through a weak supply.
- Lower B+ than the schematic shows.
- Bulging tops, leaking residue or a fishy smell from a cap.
- A blown fuse or a red-plating power tube (a leaky coupling cap can put positive DC on a power tube's grid).
Check a coupling cap for leakage: with the amp idling, measure the DC voltage on the power tube's grid (the side of the coupling cap away from the preamp). It should read the bias voltage, negative. A positive reading, or less negative than the bias supply, means the cap is leaking.
Try It
Find your amp's schematic and mark the filter caps, the bias caps and the coupling caps. Then look at the date codes on the filter caps: if they're original to an amp from the 1990s or earlier, they're likely due.
Level 2 covers choosing replacements: voltage, capacitance, temperature and type.