Amplifiers · On the Bench: The Cap Job

On the Bench: The Cap Job - Level 1: Which Caps Age and Why

Filter, bias, cathode bypass and coupling caps, why electrolytics dry out, the signs of tired caps, and checking a coupling cap for leakage.

Read it in the app ▸

A "cap job" is replacing the capacitors in an amp that have aged out. It's one of the most common repairs on an old tube amp, and one of the most misunderstood: some caps wear out and some don't, and replacing the wrong ones changes the tone for nothing. This level covers which caps age, why, and the signs. Level 2 covers choosing replacements; Level 3 covers doing the job.

DANGER: LETHAL VOLTAGE. A tube amp's filter capacitors can hold a lethal charge for hours or days after it is unplugged, and the cap job is done right where that charge lives. Unplug the amp, drain every filter cap, and check each one with a meter before you touch anything. The Cap Drain & Bleeder Calculator shows how. New to working inside an amp? Start with On the Bench: Safe Practice.

The Caps in a Tube Amp

Cap Job Ages?
Filter caps (big electrolytics near the power transformer) smooth the B+ and store its energy yes: the main reason for a cap job
Bias supply caps (small electrolytics, fixed-bias amps) smooth the negative bias voltage yes, and a failure can let the power tubes run away
Cathode bypass caps (small electrolytics on the preamp and cathode-biased power tubes) set gain and tone at each stage yes, more slowly
Coupling caps (film or paper, between stages) pass the signal, block the DC rarely wear out; old paper and some early types can leak DC
Tone and small ceramic or mica caps shape the tone almost never

Why Electrolytics Age

An electrolytic capacitor holds a liquid or paste electrolyte. Over the years it dries out, faster when hot, and the cap loses capacitance and gains internal resistance. A long-unused amp has a second problem: the insulating layer inside the cap weakens, so it can fail when power returns. Many techs treat filter caps of 15 to 25 years as due, sooner in an amp that runs hot.

The Signs

Check a coupling cap for leakage: with the amp idling, measure the DC voltage on the power tube's grid (the side of the coupling cap away from the preamp). It should read the bias voltage, negative. A positive reading, or less negative than the bias supply, means the cap is leaking.

Try It

Find your amp's schematic and mark the filter caps, the bias caps and the coupling caps. Then look at the date codes on the filter caps: if they're original to an amp from the 1990s or earlier, they're likely due.

Level 2 covers choosing replacements: voltage, capacitance, temperature and type.

Next: On the Bench: The Cap Job, Level 2: Choosing Replacements ▸