PALMATOWN/ tools / library Open the app ▸

Amplifiers · Vox

Vox, Level 3X: On the Bench

AC30 and AC15 at the bench: cathode-biased EL84s with no bias to set, the hot cathode resistor and bypass cap, sockets, EF86 microphonics.

Read it in the app ▸

The AC30 and AC15 run their EL84s cathode biased, with no negative feedback, and they run hot. That makes the bench work simpler in one way, with no bias to set, and harder in another: heat ages everything near the power tubes. The procedures are in the On the Bench series: Biasing a Tube Amp, Replacing Tubes, The Cap Job and Speakers and Cabs.

DANGER: LETHAL VOLTAGE. Hundreds of volts DC are live inside whenever this amp is on, and the filter caps hold a lethal charge after it is unplugged. Drain and measure before touching anything inside, and follow the one-hand rule on a live amp. The Cap Drain & Bleeder Calculator shows how; new to working inside an amp? Start with On the Bench: Safe Practice.

What Yours Has

Model Power section Bench notes
AC30 4 x EL84, cathode biased (30 W) no bias adjustment; runs hot
AC15 2 x EL84, cathode biased (15 W) the same approach; early versions with the EF86 can turn microphonic
AC50, AC100 EL34s a different, fixed-bias design
1970s Dallas Arbiter era silicon rectifier, PCB construction different parts and layouts from the 1960s amps

On the Bench

Quirks

Buying One Used

Try It

Measure the voltage across your AC30 or AC15's cathode resistor and divide by its resistance to get the current for the tubes sharing it. Open the Tube Bias Calculator, pick your amp's power tubes, and measure its plate voltage to find the target.

Read it in the app ▸