Level 1 covers setting up and cabling a rig, and Level 2 covers the controls of each module. This article is the numbers page and the repair bench. Only confirmed figures are filled in. Every cell that says not verified is a gap, not a zero, so read it from your own unit's rear tag, the owner's manual, or a meter.

The AC or DC Question

The short answer is that the Rockmodule wall adapter is AC, not DC, and that not every Rockmodule has a wall adapter at all.

What is settled: the export wall adapter is 12 V AC, and US units run from the mains through an internal transformer. What is not settled: the current rating of the 12 V AC adapter, the barrel plug dimensions, and whether any export model shipped with something different.

Power and Internal Rails

Module Internal rails US/Canada mains-side rating Export supply
Sustainor, Distortion Generator, Stereo Echo, Stereo Chorus plus and minus 8 V 3 W tag 12 V AC, barrel plug
Stereo Chorus/Delay plus and minus 6 V 3 W tag 12 V AC, barrel plug
Instrument EQ plus and minus 12 V 3 W tag 12 V AC, barrel plug
Midi Octopus single 5 V 3 W tag 12 V AC, barrel plug
Guitar Compressor, Smart Gate plus and minus 8 V 3 W tag 220 V AC version sold without a plug; 12 V AC not verified
Dual Remote Loop, Triple Footswitch not verified not verified not verified
Midipedal not verified own mains cord, voltage printed on rear panel not verified

The 3 W tag works out to roughly 30 mA from a 110 V outlet. That is a mains-side figure, and it is stated for Rockmodules as a group, not measured per box. The current drawn from a 12 V AC adapter is not verified for any module, so there is no mA number to quote for the export supply. Some dealer listings quote "12 V AC, 60 Hz, 3 W" and one quotes 500 mA. These are different kinds of rating and do not settle the draw.

Impedances, Levels and Physical Data

Module Input impedance Output impedance Nominal levels Connectors confirmed Size and weight
Sustainor 2 megohms not verified not verified three rear footswitch jacks, external loop half-rack; about 700 g
Stereo Chorus/Delay 2 megohms not verified drive switch minus 6, 0, plus 10 dB; level not verified three footswitch inputs half-rack; weight not verified
Distortion Generator 2 megohms not verified not verified no external loop half-rack; not verified
Stereo Echo 2 megohms not verified not verified stereo input, or mono via left jack half-rack; not verified
Stereo Chorus 2 megohms not verified not verified four rear control jacks half-rack; not verified
Instrument EQ, Guitar Compressor, Smart Gate 2 megohms not verified not verified not verified half-rack; not verified
Midi Octopus, Dual Remote Loop not verified not verified not verified MIDI control of the rack (Octopus); jack list not verified half-rack; not verified
Racktray not applicable not applicable not applicable none holds two modules; dimensions not verified

The 2 megohm figure comes from the design, where an op amp buffer sets the input impedance of every Rockman audio input. Outputs are described only as low enough to drive other gear without losing high frequencies, and they are unbalanced. The audio jack size on each module is not verified, so measure before you build a case or shelf.

Bench Guide: Power First

Do the cheap checks before you open anything.

  1. Read the tag. Note the mains voltage, the 3 W rating and whether the unit is a mains-cord model or an export model that expects a wall adapter.
  2. Inspect the cord or adapter. Export wall adapters have a fragile cord and a weak barrel plug. Wiggle-test them and look for a cracked plug before you blame the module.
  3. Measure the adapter. With a multimeter on AC volts, read the output with the adapter plugged into the wall. A plain transformer adapter commonly reads higher with no load than under load, so a reading somewhat above 12 V is not alarming. A reading near zero means a dead adapter.
  4. Check polarity. AC has no polarity, so there is no centre pin to get wrong. If an adapter says DC, the module does not want it.

Substituting an Adapter Safely

For a lasting fix on an export unit, a technician can fit an internal transformer, which also removes the weak cord and plug.

Common Faults